Check for 120v across from L1 and L2 on CV thermostat.
If you have 120v then thermostat is faulty.
If no 120v then check for 120v from terminal 3 of main power switch to case ground.
If no 120v then check for 120v from terminal 4 of main power switch to case ground.
If 120v to terminal 4, but not terminal 3 then NO block on main power switch faulty.
If no 120v on terminal 4 then check for 120v across A & B coils on clear relay behind control panel.
If no 120v across A & B then check for 120v from B coil to case ground.
If 120v from B to case ground then relay not closing and is faulty.
If no 120v from B to case ground then check for 120v from terminal 3 of rotisserie advance button to case ground.
If 120v from terminal 3 of rotisserie advance button to case ground, but not from B on clear relay to case ground the door switch is faulty.